Cannabis grow room HVAC + dehumidification

Cannabis grow room HVAC.
Built for your crop.

Custom HVACD systems for commercial cannabis grow rooms. Cooling, dehumidification, modulating hot gas reheat and PLC controls coordinated around your facility's room loads.

HOT GAS REHEATDEW-POINT PRIORITYINTERNAL PLC4–60 TON PLATFORM
Yield Logic Summit Series HVACD unit
CONTROL MODEDEHUM + REHEAT
ROOM STRATEGYONE SYSTEM

The equipment-stack problem

Your plants experience one environment.
Your equipment should act like one system.

CONVENTIONAL APPROACH

More devices. More interfaces.

  • Multiple DX cooling units
  • Standalone dehumidifiers
  • Electric or gas reheat
  • Separate stats, humidistats, or BMS logic
  • More feeders, drains, controls, and service points
VS
YIELD LOGIC HVACD

One coordinated room strategy.

  • Integrated cooling + moisture removal
  • True modulating hot gas reheat
  • Dew-point-priority dehumidification
  • Internal PLC with simple local control
  • Fewer devices and a clearer service path

Engineered for real cultivation loads

The room is the system.

Lighting, canopy density, irrigation, airflow, and plant transpiration all shape the HVACD load. Yield Logic starts with the actual cultivation environment and builds the control strategy around it.

Yield Logic Extreme Series brushed stainless HVACD unit
EXTREME SERIESBuilt for demanding environments

Precision through integration

Dehumidify hard.
Hold the temperature.

Yield Logic cools the airstream below its dew point to remove moisture, then redirects available compressor heat to temper the dried air before it returns to the room. The PLC coordinates the sequence around room demand.

Extreme Series: Engineered for demanding indoor and outdoor environments, with enhanced features and specialized protective coatings for corrosion resistance in harsh conditions.

01SENSETemperature, RH, dew point
02CONDENSERemove sensible + latent load
03REHEATReclaim available discharge heat
04RETURNDeliver conditioned air

Built for the finish

Control the conditions that protect saleable flower.

Stable temperature, humidity, dew point, and VPD support a repeatable late-flower strategy without forcing cooling and dehumidification equipment to fight each other.

01

Hold a drier finish

Continue removing moisture as sensible demand falls—especially during lights-off and late flower.

02

Reduce the equipment stack

Consolidate functions that may otherwise require multiple units, reheat devices, controllers, and connections.

03

Reclaim the heat

Use available refrigeration heat for reheat instead of purchasing the modeled reheat duty again.

04

Operate locally

Manage essential setpoints, staging, alarms, and sequences through the integrated internal PLC.

Environmental stability can support yield and quality potential, but crop outcomes depend on genetics, cultivation practices, airflow, sanitation, irrigation, and other facility factors. No yield improvement is guaranteed.

Yield Logic HVACD unit installed in a cultivation facility

Custom-built around the operation

From the room load
to the crop plan.

Flower RoomsVeg RoomsPropagationDry + CureVertical FarmsResearch

Packaged and split configurations are selected around lighting load, plant moisture, day/night targets, outside design conditions, utilities, redundancy, access, and service strategy.

Technical HVACD resources

Start with the grow-room load.

Learn how purpose-built cannabis HVACD and modulating hot gas reheat support temperature, humidity, dew point, and VPD control through lights-on, lights-off, and late flower.

APPLICATION GUIDECannabis Grow Room HVACD SystemsCooling, dehumidification, airflow, dew point, and VPD control → TECHNOLOGY GUIDEHot Gas Reheat HVACDHow reclaimed refrigeration heat tempers dehumidified air → MOISTURE CONTROL GUIDECannabis Grow Room DehumidificationLatent loads, lights-off control, dew point, VPD and retrofit planning → LIGHTING × HVACDGrow Room Lighting & HVACD CorrelationLighting watts drive sensible heat; crop moisture drives latent load; staged YL 15 matches lights on/off → LOAD DESIGN GUIDECannabis Grow Room HVAC SizingSize sensible and latent capacity from the room—not a square-foot shortcut → SYSTEM COMPARISONIntegrated HVACD vs Mini-Splits and DehumidifiersEquipment stack or one coordinated system: lights-off control, energy, install cost and service → BUDGET GUIDECannabis Grow Room HVAC Cost GuidePublic installed-cost ranges, what drives price, and operating and service costs → RETROFIT GUIDEGrow Room Humidity Spikes at Lights-OffWhy humidity spikes at lights-off and the HVACD retrofit options that fix it → POST-HARVEST GUIDECannabis Dry and Cure Room HVACDDry and cure room temperature, humidity, airflow and HVACD design → FLORIDA GUIDEFlorida Grow Room HVACDHVACD for Florida MMTC cultivation rooms: humidity, lights-off control and build timing → VPD CONTROL GUIDEVPD and Dew-Point Control in Grow RoomsVPD, RH and dew point, lights-off control, and what to give your designer → OPERATING COST GUIDEGrow Room Demand ChargeskW vs kWh, 15-minute peaks, and a power cost estimate calculator →

Beyond the mechanical system

Cannabis facility design, beyond the HVAC system.

Yield Logic handles the HVACD portion of cannabis facility design. For the complete cultivation facility, Visions Contracting coordinates construction, electrical, HVACD, horticultural lighting, controls, specialty interiors and commissioning.

Explore Visions Full-Facility Design-Build

Start with the room—not a rule of thumb

Let’s engineer the HVACD
around your crop.

Bring the room dimensions, canopy area, lighting wattage and schedule, environmental targets, location, and baseline equipment. Yield Logic will develop a custom concept and project quote.

Info@VisionsContractingLLC.com